Pluggable 4-Pole 3-Phase SPDs have DIN rail-mount design.

2015-09-11 14:31:07| Industrial Newsroom - All News for Today

Configured with protection mode of Line-Ground and Neutral-Ground, pluggable 3-phase 4-pole Surge Protection Devices (SPDs) are UL Type 4 recognized and available with MCOV ratings of 150, 180, 275, 320, 420, 550, and 690 Vac. Thermal disconnect design accelerates thermal response time, protecting electrical equipment from incoming impulses, surges, and transient voltages. Each voltage module has unique voltage key to ensure appropriate voltage module and base are connected.

Tags: design din pluggable 3phase

 

PCB Terminal Blocks come in fixed and pluggable versions.

2015-07-21 14:31:07| Industrial Newsroom - All News for Today

Pluggable PCB terminal blocks come in standard, miniature, vertical, and high current varieties. Available in 2–24 positions with 12–24 AWG wire range, standard versions are rated for 12 A at 300 V. Fixed versions come in standard, miniature, 45°, double level, modular, and wire protection varieties. Standard versions are available with pin spacing from 3.5–10.16 mm. Also available, spring clamp terminal blocks with 3.5–7.62 mm pin spacing accelerate connection of individual wires to PCB.

Tags: fixed versions terminal blocks

 
 

Industrial Connectors make distribution lines pluggable.

2015-03-30 14:31:05| Industrial Newsroom - All News for Today

Available with Han-Yellock® as well as other Han® series connectors, Bridge Block makes multiplication in connector possible. Bridging function replaces terminal blocks in switching cabinet and is installed in connector quickly with low demands on space. Bridge block is offered in 3 sizes of Han-Modular® inserts with up to 15 Han E® contacts. Compatible with HanModular® hinged frames, Han-Yellock® bridge block can be applied in all hinged frame applications from size 10B and up.

Tags: make industrial distribution lines

 

Anritsu Company to Be Part of OIF Technology Demonstration Highlighting 56G Interfaces and Pluggable Coherent Optics

2015-03-30 12:31:11| Industrial Newsroom - All News for Today

- MP1800A BERT and MZ1834A 4PAM Converter to be Part of CEI-56G-VSR-PAM QSFP Compliance Demonstration - RICHARDSON, Texas  Anritsu Company (OFC booth #1309) will be participating in live technology demonstrations to be conducted by the Optical Internetworking Forum (OIF) at OFC 2015 scheduled for March 24-26 in...

Tags: part company technology interfaces

 

Client-Side Transceiver has 100G pluggable MSA form factor.

2015-03-09 13:31:06| Industrial Newsroom - All News for Today

Able to deliver 100 GbE and OTU4 data rate performance while consuming 4 W typ, 100G LR4 CFP4 enables high-end core router and packet-optical transport systems to increase front panel density to meet bandwidth demands of datacenter interconnects and network operators. SFF design, backwards compatible with existing Oclaro CFP and CFP2 LR4 designs, leverages indium phosphide (InP) 28G core electro-absorption modulated laser (EML) technology.